CDDL HEADER START
The contents of this file are subject to the terms of the
Common Development and Distribution License (the "License").
You may not use this file except in compliance with the License.
You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
or http://www.opensolaris.org/os/licensing.
See the License for the specific language governing permissions
and limitations under the License.
When distributing Covered Code, include this CDDL HEADER in each
file and include the License file at usr/src/OPENSOLARIS.LICENSE.
If applicable, add the following below this CDDL HEADER, with the
fields enclosed by brackets "[]" replaced with your own identifying
information: Portions Copyright [yyyy] [name of copyright owner]
CDDL HEADER END
Portions Copyright 2007 Sun Microsystems, Inc.
.. highlight:: none
Message ID: ZFS-8000-9P
=======================
Failing device in replicated configuration
------------------------------------------
+-------------------------+----------------------------------------------------+
| **Type:** | Error |
+-------------------------+----------------------------------------------------+
| **Severity:** | Minor |
+-------------------------+----------------------------------------------------+
| **Description:** | A device has experienced uncorrectable errors in a |
| | replicated configuration. |
+-------------------------+----------------------------------------------------+
| **Automated Response:** | ZFS has attempted to repair the affected data. |
+-------------------------+----------------------------------------------------+
| **Impact:** | The system is unaffected, though errors may |
| | indicate future failure. Future errors may cause |
| | ZFS to automatically fault the device. |
+-------------------------+----------------------------------------------------+
.. rubric:: Suggested Action for System Administrator
Run ``zpool status -x`` to determine which pool has experienced errors:
::
# zpool status
pool: test
state: ONLINE
status: One or more devices has experienced an unrecoverable error. An
attempt was made to correct the error. Applications are unaffected.
action: Determine if the device needs to be replaced, and clear the errors
using 'zpool online' or replace the device with 'zpool replace'.
see: https://openzfs.github.io/openzfs-docs/msg/ZFS-8000-9P
scrub: none requested
config:
NAME STATE READ WRITE CKSUM
test ONLINE 0 0 0
mirror ONLINE 0 0 0
c0t0d0 ONLINE 0 0 2
c0t0d1 ONLINE 0 0 0
errors: No known data errors
Find the device with a non-zero error count for READ, WRITE, or
CKSUM. This indicates that the device has experienced a read I/O
error, write I/O error, or checksum validation error. Because the
device is part of a mirror or RAID-Z device, ZFS was able to recover
from the error and subsequently repair the damaged data.
If these errors persist over a period of time, ZFS may determine the
device is faulty and mark it as such. However, these error counts may
or may not indicate that the device is unusable. It depends on how
the errors were caused, which the administrator can determine in
advance of any ZFS diagnosis. For example, the following cases will
all produce errors that do not indicate potential device failure:
- A network attached device lost connectivity but has now
recovered
- A device suffered from a bit flip, an expected event over long
periods of time
- An administrator accidentally wrote over a portion of the disk
using another program
In these cases, the presence of errors does not indicate that the
device is likely to fail in the future, and therefore does not need
to be replaced. If this is the case, then the device errors should be
cleared using ``zpool clear``:
::
# zpool clear test c0t0d0
On the other hand, errors may very well indicate that the device has
failed or is about to fail. If there are continual I/O errors to a
device that is otherwise attached and functioning on the system, it
most likely needs to be replaced. The administrator should check the
system log for any driver messages that may indicate hardware
failure. If it is determined that the device needs to be replaced,
then the ``zpool replace`` command should be used:
::
# zpool replace test c0t0d0 c0t0d2
This will attach the new device to the pool and begin resilvering
data to it. Once the resilvering process is complete, the old device
will automatically be removed from the pool, at which point it can
safely be removed from the system. If the device needs to be replaced
in-place (because there are no available spare devices), the original
device can be removed and replaced with a new device, at which point
a different form of ``zpool replace`` can be used:
::
# zpool replace test c0t0d0
This assumes that the original device at 'c0t0d0' has been replaced
with a new device under the same path, and will be replaced
appropriately.
You can monitor the progress of the resilvering operation by using
the ``zpool status -x`` command:
::
# zpool status -x
pool: test
state: DEGRADED
status: One or more devices is currently being replaced. The pool may not be
providing the necessary level of replication.
action: Wait for the resilvering operation to complete
scrub: resilver in progress, 0.14% done, 0h0m to go
config:
NAME STATE READ WRITE CKSUM
test ONLINE 0 0 0
mirror ONLINE 0 0 0
replacing ONLINE 0 0 0
c0t0d0 ONLINE 0 0 3
c0t0d2 ONLINE 0 0 0 58.5K resilvered
c0t0d1 ONLINE 0 0 0
errors: No known data errors
.. rubric:: Details
The Message ID: ``ZFS-8000-9P`` indicates a device has exceeded the
acceptable limit of errors allowed by the system. See document
`203768 <http://web.archive.org/web/20090409151209/http://sunsolve.sun.com/search/document.do?assetkey=1-61-203768-1&searchclause=203768/>`__
for additional information.