From 402b01656d34b28d28bd3cfe2fc5d248429c222b Mon Sep 17 00:00:00 2001 From: Paul Steinbach Date: Tue, 17 Nov 2020 15:49:49 -0500 Subject: [PATCH] Corrected typo in "power off" (#75) --- docs/Performance and Tuning/Hardware.rst | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/docs/Performance and Tuning/Hardware.rst b/docs/Performance and Tuning/Hardware.rst index d42a4a5..fd8f40e 100644 --- a/docs/Performance and Tuning/Hardware.rst +++ b/docs/Performance and Tuning/Hardware.rst @@ -773,7 +773,7 @@ specification therefore require higher end UPS units for protection to ensure that the transfer time does not exceed the hold-up time. A hold-up time below the transfer time during a transfer to battery power can cause undefined behavior should the PWR_OK signal not become -deasserted to force the machine to poser off. +deasserted to force the machine to power off. If in doubt, use a double conversion UPS unit. Double conversion UPS units always run off the battery, such that the transfer time is 0. This